An EICR is only as useful as the person carrying out the inspection. If you are a landlord facing a deadline, a facilities manager responsible for a busy site, or a homeowner concerned about an ageing installation, knowing who issues EICRs helps you avoid a report that is incomplete, unreliable or not accepted when you need it.

An Electrical Installation Condition Report, usually called an EICR, should be issued by a competent electrical professional after a thorough inspection and testing of the fixed wiring in a property. It is not a certificate that can be produced from a quick visual check, and it should never be treated as a paperwork exercise.

Who can issue an EICR?

An EICR can be issued by an electrician or electrical contractor who is competent to inspect, test and report on electrical installations. In practice, that means someone with the right technical knowledge, relevant inspection and testing qualifications, suitable test equipment and current understanding of BS 7671, the IET Wiring Regulations.

The person completing the report must be able to assess the installation properly, identify defects, record test results accurately and make sound recommendations. They also need enough experience to understand the type of premises being inspected. Testing a small domestic flat is different from inspecting a warehouse, office, retail unit or industrial facility with three-phase supplies and operational machinery.

There is no single government-issued EICR licence. However, choosing an electrician registered with a recognised competent person scheme, such as NICEIC, provides useful reassurance. NICEIC-approved contractors are assessed against standards covering technical competence, procedures, insurance and the quality of their work. It also gives customers a clear route to check credentials before booking.

What qualifications should the inspector have?

You do not need to become an electrical expert to appoint the right contractor, but you should be comfortable asking a few direct questions. A competent EICR provider should hold appropriate inspection and testing qualifications and be able to demonstrate practical experience of the work involved.

For commercial and industrial properties, the contractor should also understand your environment. This may include emergency lighting, distribution boards, containment, plant rooms, high-load equipment, fire safety interfaces, shutdown procedures and the need to keep disruption to a minimum. The lowest quote is not always the best value if the inspector does not allow enough time to test the installation properly.

Professional registration is not the only measure of competence, but it is a sensible starting point. Ask whether the business is NICEIC-approved or registered with another recognised scheme, whether it is fully insured, and whether the individual carrying out the work is qualified for inspection and testing. A reputable contractor will answer clearly and explain what their quotation covers.

Who does not issue a valid EICR?

A landlord, letting agent, estate agent or property manager cannot issue an EICR unless they are also suitably qualified and competent to inspect and test electrical installations. Similarly, a general handyman or someone who only carries out basic electrical jobs should not be asked to produce an electrical condition report.

Local authorities do not issue EICRs either. They may request a satisfactory report as part of their enforcement responsibilities, particularly in rented housing, but the inspection itself must be completed by a competent electrical professional.

Be cautious if someone offers a certificate without testing. An EICR requires both visual inspection and electrical testing. Depending on the property, this can involve checking protective devices, earthing and bonding arrangements, socket circuits, lighting circuits, consumer units or distribution boards, insulation resistance and circuit continuity. Access limitations may affect what can be tested, but they must be recorded honestly within the report.

What happens during an EICR inspection?

The electrician begins by reviewing the installation and identifying the circuits, equipment and areas to be inspected. They then carry out visual checks and a series of dead and live tests where safe to do so. In a commercial setting, this should be planned around your trading hours, production activity and any areas that cannot be taken out of service without notice.

Some interruption is often necessary. Circuits may need to be isolated briefly for testing, and sensitive equipment may need to be shut down safely. A professional contractor will explain this before work starts, agree an appropriate testing plan and keep you informed if an issue affects the scope or timing of the inspection.

Once complete, the inspector issues the EICR with observations coded according to their severity. A C1 observation identifies danger requiring immediate action. C2 indicates a potentially dangerous condition that needs urgent remedial work. FI means further investigation is required without delay. A report containing C1, C2 or FI observations will normally be recorded as unsatisfactory until the issues are addressed or investigated.

A C3 observation is an improvement recommendation and does not, by itself, make the report unsatisfactory. This distinction matters. Not every older installation needs a full rewire simply because it does not match the latest edition of the Wiring Regulations. The inspector should assess safety, not sell unnecessary work.

Do landlords need an EICR from a qualified electrician?

Yes. In England, private landlords must ensure the electrical installation in a rented property is inspected and tested by a qualified and competent person at least every five years, or more often if the report recommends it. They must provide tenants with a copy of the report and retain records as required.

The rules vary across the UK and can also differ by property type, tenancy arrangement and local licensing requirements. Social housing providers, managing agents and landlords of houses in multiple occupation may have additional duties. If you manage a portfolio, it is sensible to use one dependable contractor who can schedule inspections, provide clear documentation and complete remedial work promptly where required.

Homeowners are not generally under the same statutory five-year duty, but an EICR remains a practical safety measure. It is particularly worthwhile when buying an older property, before major renovation work, after flooding or damage, when installing high-demand equipment such as an EV charger, or if the electrics have not been checked for many years.

How often should a business have an EICR?

The right interval depends on the type of premises, the condition of the installation and how it is used. Many commercial properties are inspected every five years, while industrial environments, public spaces, accommodation and locations exposed to greater wear, moisture, heat or mechanical damage may require more frequent testing.

Your existing EICR should state the recommended date for the next inspection. That recommendation is based on the inspector’s assessment of the installation, not just a standard calendar reminder. If your use of the building changes significantly – for example, you add machinery, alter layouts, increase electrical loads or convert office space into a workshop – an earlier assessment may be appropriate.

What to check before booking an EICR

Before appointing an electrician, confirm what will be inspected, whether the price includes the certificate, and how remedial work will be quoted if defects are found. For larger properties, ask whether the contractor has allowed sufficient time and whether there is a limit on circuits, distribution boards or test points within the quoted price.

It is also worth checking who will sign the report. In some firms, one electrician completes the testing while a qualified supervisor reviews and authorises the documentation. This can be entirely appropriate, provided the process is properly managed and the report is based on genuine inspection and testing.

FCR Electrical Ltd provides EICRs for domestic, commercial and industrial clients with a practical focus on compliance, clear reporting and minimal disruption. As a NICEIC-approved contractor, the team can identify faults, explain the options plainly and carry out necessary remedial works without leaving you to coordinate multiple trades.

A good EICR should leave you with more than a certificate. It should give you a clear picture of your installation’s condition, the actions that need taking and confidence that the work has been assessed by someone qualified to put safety first.