What is an Electrical Inspection and Condition Report (EICR)?
An Electrical Inspection and Condition Report or EICR as it is more commonly called is a series of electrical tests and a visual inspection of an electrical installation to assess it’s satisfactory condition for the installations ongoing safe use.
Book a Residential Electrical Inspection and Condition Report (EICR) >
Book a Commercial Electrical Inspection and Condition Report (EICR) >
To build an informed view of this, one of our appropriately qualified and experienced electrical technician's will perform a detailed visual examination of the installation along with appropriate electrical tests. From the results of the visual inspection and electrical testing, our technician will create a report and make an informed assessment of the continued safety of the electrical installation.
We carry out EICR electrical inspections across Manchester, Stockport, Cheshire, Wilmslow, Altrincham, Warrington, Preston, Blackpool, Lancashire and the wider North West. We also travel nationally for commercial clients — contact us for a quotation.
Why Do I Need A Electrical Installation Condition Report?
An Electrical Installation Condition Report is carried out as far as is reasonably practicable for
• The safety of persons and livestock against the effects of electric shock and burns
• Protection against damage to property by fire and heat arising from an installation defect.
• Confirmation that an installation is not damaged or deteriorated so as to impair safety.
• The identification of installation defects and departures from the requirements of B.S7671 (The electrical wiring regulations) that may give rise to danger.
When would I need an EICR carried out?
You may need an Electrical Inspection Condition Report carrying out for the following.
• The purchase of a new home
• At the request of licencing authorities, public bodies, insurance companies, mortgage lenders, and others that may require periodic inspection and testing such as HMO's.
• A change of occupancy of the premises (especially rented domestic accommodation)
• After additions/alterations of the premises
• Where there is reason to believe that damage may have been caused to the installation, such as after a flood.
Recommended Frequencies Of Inspection of Electrical Installations
| Type of installation | Routine check | Maximum period between inspections | Book online |
|---|---|---|---|
| Domestic accomodation: general | - | Change of occupancy / 10 years | Book online |
| Domestic accomodation: rented houses and flats | 1 year | 5 year | Book online |
| Residential accomodation (HMOs): hall of residence, nurses' accomodation, etc. | 1 year | 5 years | Book online |
| Commercial | 1 year | 5 years | Enquire now |
| Educational establishments | 6 months | 5 years | Enquire now |
| Industrial | 1 year | 3 years | Enquire now |
| Offices | 1 year | 5 years | Enquire now | Shops | 1 year | 5 years | Enquire now |
Classification Of Danger And Non-Compliances (for use during periodic inspection and testing)
| Classification Of Danger or Non-Compliance | Description | Guidance |
|---|---|---|
| C1 | Danger present. Risk of injury. Immediate remedial action required. | To be attributed to matters that cannot be left. It is suggested that these are rectified or possibly, that isolation may be recommended or necessary. Examples include accessible bare live parts, badly damaged equipment with risk of access to live parts, incorrect polarity, and/or arcing or burning found in switchgear. |
| C2 | Potentially dangerous: urgent remedial action required. | To be attributed to issues that, while urgent, do not require immediate remedial action. Examples include non-earthered installation (this requires a further fault to result in danger), fundamentally undersized cables, EFLI values greater than required by BS 7671, a "borrowed" neutral, equipment with inappropiately selected IP (this may warrant C1 if severe), insulation reading under 1 mΩ and connections not housed within appropriate enclosures. |
| C3 | Improvement recommended | To be attributed where C1 or C2 do not apply. Examples include the absence of most warning notices, absence of the required diagrams and charts, no or incorrect marking of conductors at terminations, and absence of an RCD specified for additional protection (where the circuit otherwise tests as normal). |
| FI | Further investigation required without delay. | To be attributed where the inspection has revealed an apparent deficiency that could not, due to the limitation or extent of the inspection, be fully indentified and where further investigation may reveal a C1 or C2 item. An example could be where characteristics of electricity supply (such as voltage or external EFLI) do not conform to supply industry norms. Mayb also be used where part of an installation included in the scope of the inspection and test could not be accessed. |
To find our more about the EICR codes click here EICR coding
How much do our EICR services cost?
| Service | Price | Book online |
|---|---|---|
| 1 Bedroom - EIRC Certification | £165 + VAT | Book now |
| 2 Bedroom - EIRC Certification | £185 + VAT | Book now |
| 3 Bedroom - EIRC Certification | £225 + VAT | Book now |
| 4 Bedroom - EIRC Certification | £255 + VAT | Book now |
| 5+ Bedroom - EIRC Certification | POA | Contact us |
What is an EICR?
EICR stands for Electrical Installation Condition Report. It's an inspection and test of the fixed wiring in a property: the consumer unit, circuits, sockets, switches and light fittings. The electrician checks for damage, wear, overloading and anything that doesn't meet current safety standards, then gives each problem a code to show how urgent it is. The report says whether the installation is satisfactory or unsatisfactory and recommends when the next inspection should be.
Landlords in England have to have one at least every five years; for homeowners, it's a good idea when you buy a house or if the wiring is old. If you want to understand what the report might mean for a rewire, see our guide: How can I tell if my house needs rewiring?
Electrical Safety Inspections Services
FCR Electrical provide the full range of EICR and electrical safety inspection services for domestic and commercial clients across the North West:
- Landlord EICR — legal requirement every 5 years for all rental properties
- Homeowner EICR — recommended every 10 years or before buying/selling a property
- HMO Electrical Inspection — required annually for houses in multiple occupation
- Commercial EICR — for offices, warehouses, retail units and industrial premises
- Educational Establishment Inspection — schools, colleges and training facilities
- Caravan Park & Holiday Site EICR — for pitch connections and site infrastructure
- Pre-purchase Electrical Survey — before buying a property
- Insurance-required EICR — for mortgage lenders, insurers and licensing authorities
- Emergency EICR — fast-turnaround reports where required
All inspections are carried out by NICEIC-approved engineers and include a full written report with clear classification of any defects found (C1, C2, C3 or FI). Where remedial work is required, we can carry this out immediately to get your property compliant as quickly as possible.
Book services online
Qualified & Accredited
Our latest EICR jobs More EICR Jobs
EICR Report Explained Clearly
EICR report explained clearly for landlords, businesses and homeowners - what the codes mean, what happens next, and...
View Job
Landlord Electrical Safety Guide for UK Rentals
A practical landlord electrical safety guide for UK rentals, covering EICRs, legal duties, warning signs, remedial work...
View Job
Church Hall Rewire at The Well Church, Lytham St Annes. Full Electrical Upgrade Including EICR and Three-Phase Mains Distribution
At FCR Electrical Ltd, we recently completed a significant church hall rewiring project at The Well Church in Lytham...
View Job
✅ Commercial EICR in Liverpool
Electrical Inspection for Motor Range by FCR Electrical FCR Electrical recently had the pleasure of completing a 5-year...
View JobWhy Choose FCR Electrical to carry out your Electrical Inspection Condition Report?
✅ NICEIC-Approved & TrustMark Registered — all reports legally compliant
✅ Over 20 Years of Electrical Inspection Experience
✅ Fast Turnaround — reports issued promptly after inspection
✅ Competitive Rates for Portfolio Landlords and Managing Agents
✅ Remedial Work Carried Out In-House — no need for a second contractor
✅ Covering Manchester, Stockport, Cheshire, Lancashire and the North West
✅ 24-Hour Emergency Callout Service Available
✅ 70 Five-Star Google Reviews
✅ Clear, Jargon-Free Reports with Plain-English Explanations
![]()
Ask any questions about our EICR services.
Simply complete the form below and a friendly member of the FCR Electrical team will contact you shortly.
Based in Lancashire with direct access to the M6, M60 and M62 motorway networks, FCR Electrical are perfectly placed to carry out EICR inspections across Manchester, Stockport, Cheshire and the wider North West. Complete the form below and a member of our friendly team will be in touch to arrange your inspection at a time that suits you. For landlords with multiple properties, please mention your portfolio size and we will provide a competitive package rate..